Home >> Services >> Implant Dentistry >> Dental Implants >> NobelPerfect™
NobelPerfect™

The scalloped design, introduced with NobelPerfect™, has started a new era in implant dentistry, namely Soft Tissue Integration™. For the frst time, esthetics and biology go hand-in-hand in a three-dimensional osseous ridge. The anatomic design and the unique implant surface, TiUnite™, give esthetic support and an effective barrier against the oral cavity.

NobelPerfect™ is a unique, anatomically designed implant for esthetically demanding areas from premolar to premolar. Thanks to the anatomic design, the interproximal bone may be preserved in situations where the three-dimensional ridge topography results in a height discrepancy between the facial and interproximal aspect of the osteotomy.

  • Scalloped bone apposition area follows three-dimensional osseous contours.
  • Scalloped soft tissue apposition area allows for the development of the biologic width around the entire neck of the implant.
  • Scalloped prosthetic table follows three-dimensional soft tissue topography.

The NobelPerfect™ One-Piece implant follows these principles and is machined from a single piece of titanium, incorporating both the implant body and an integral fxed abutment. The scalloped TiUnite surface contour at the implant neck follows the same principles as for the original NobelPerfect™.

The One-Piece design allows placement flexibility of the implant, as the final margin of the implant is prepared in the same way as for a natural tooth. With this design, the soft tissue is supported entirely by the implant body, irrespective of the shape of the osseous ridge.

Minimal Surgical Invasion

NobelPerfect™ One-Piece implants are placed in a single-stage transgingival procedure. Due to the one-piece design, the surgery can be made fapless, with minimal surgical invasion. A provisional restoration can be placed at the time of surgery. After healing, the abutment section of the implant can be prepared and restored like a natural tooth.

Advantages

Less Discomfort:
Patients expierence minimal discomfort, especially during a fapless procedure.

Reduced Chairtime:
The one-stage surgical procedure reduces chairtime, saving the patient time, expense and discomfort.

Immediate Function™:
An esthetic restoration can be achieved immediately, providing patients with immediate gratifcation.

Stable and Esthetic Soft Tissue:
Marginal gingival tissues and the interproximal papillae remain stable. Thanks to the scalloped design of the TiUnite surface, the interproximal bone may be preserved in situations where the three-dimensional ridge topography results in a height discrepany between the facial and interproximal aspect of the osteotomy.

Indications

A universal implant, the NobelPerfect™ One-Piece is indicated for both single and multiple sites throughout the entire mouth where the bone has a scalloped architecture.

0 0